產品展示
PRODUCT DISPLAY
產品展示您現在的位置: 首頁 > 產品展示 > 臺灣儀鼎PICOTEST > PICOTEST測試訊號轉換器 > INJB03PICOTEST儀鼎儀器專業測試訊號轉換器

PICOTEST儀鼎儀器專業測試訊號轉換器

更新時間:2017-08-09
瀏覽次數:2600
簡要描述:

PICOTEST儀鼎儀器專業測試訊號轉換器專業代理銷售現貨供應INJB01,INJB02,INGB03,J2100A.J2101A,J2102A,J2110A,J2111A,J2112A,J2120A,J2130A,J2140A,J2160A,J2180A,J2180A-20,J2190A

在線咨詢

PICOTEST儀鼎儀器專業測試訊號轉換器

INJB01測試訊號轉換器

What's included:

J2100A Injection Transformer 1Hz - 5MHz
J2101A Injection Transformer 10Hz - 45MHz
J2110A Solid State Injector
J2120A Line Injector
J2130A DC Bias Injector
J2111A Current Injector 
J2170A High PSRR Power Adapter (Shipped Separay)
User manual

PICOTEST儀鼎儀器專業測試訊號轉換器

INJB02測試訊號轉換器

What's included:
J2110A Solid State Injector
J2111A Current Injector
J2120A Line Injector
J2130A DC Bias Injector
J2140A Attenuator 
J2170A High PSRR Power Adapter
User manual

INJB03測試訊號轉換器

What's included:
J2111A Current Injector
J2101A Injection Transformer 10Hz - 45MHz
J2120A Line Injector
J2140A Attenuator 
J2170A High PSRR Power Adapter
User manual

J2100A Injection Transformer 1Hz~5MHz 

 
 
J2100A測試訊號轉換器
 
 
iconLow band corner frequency 達1Hz,可支援 功率因數控制器(PFC)之穩定性測試
icon5MHz帶寬足以量測大多數電源和穩壓器
icon超高頻寬,可達23 Octave
icon優異精確的低失真表現
icon5Ω終端,對待測電路的影響降至zui小
icon包括衰減功能來確保小信號的測量正確性
icon詳細規格
 
Product Information

The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.

The usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.

The bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.

 
Detailed Specifications:
 
Performance at -10dBm input level
CharacteristicRating
DCR 
Ratio1:1
Termination Impedance5 Ohms
Nominal 3dB Bandwidth1Hz ~ 5MHz
Isolation Voltage600V
Isolation Capacitance390pF@1KHz
DC Current10mA
Temperature Range0 ~ 50°C
Maximum Altitude6000 Ft

 J2100A測試訊號轉換器

J2100A 1 hz - 5 mhz
J2101A  10 hz - 45 mhz
J2110A
J2120A
J2130A

J2140A

J2160A

J2180A

J2180A

J2190A

 

 

聯系方式
  • 服務熱線:

    4009023318

    13913158248

    15295666126

  • 公司電話:

    0512-66315386

  • 公司傳真:

    0512-66315383

在線客服
  • 技術支持:
  • 產品咨詢:

精品无码人妻一区二区三区18
掃一掃訪問手機站掃一掃訪問手機站
訪問手機站